System sizer
Rough size your system in a minute
This is a starting point, not a final design. Send the result with your question and we’ll check it against your real loads.
How these numbers are worked out
- Solar array: daily use divided by sun hours, plus about 25 percent for wiring, heat, and inverter losses. Ohio averages about 4.5 peak sun hours a day over a year and about 2.3 in December (NREL PVWatts). The sizer plans on 4 for the year to leave room for clouds, or 2.3 when you check the winter box. Rounded up to whole 400 watt panels.
- Battery bank: daily use times days of backup gives the usable energy you need. LiFePO4 is planned at 80 percent usable, so the total bank is a bit bigger.
- Inverter: the most you run at once plus 25 percent headroom, rounded up to a common size. Motors like well pumps and compressors pull a big surge on startup, so tell us about those.
- System voltage: 12 V for small setups, 24 V for mid size, and 48 V once the inverter gets past about 3,000 watts.
These are rough planning numbers. A real design checks your actual appliances, wire runs, and where the panels will sit.